Tungsten Electrodes, Heat Treated Tapered Tip

with Polymide Tubing (MicroProbes)
Description

Tungsten is a versatile and widely-used microelectrode material that offers a good balance between performance and cost.

Advantages Disadvantages
  • Extremely strong and stiff metal provides probes with exceptional rigidity.
  • Great for acute and chronic recording due to biocompatibility and lower cost.
  • High corrosion resistance offers consistent long-term performance.
  • Does not provide the same degree of electrochemical performance or stability as platinum-iridium alloy, making it a poor alternative for microstimulation.
  • Lower charge transfer capacity of tungsten will result in larger, potentially unsafe interfacial potentials when applying the same stimulation current as to a platinum-iridium electrode.
  • Certain pH or stimulation conditions can lead to tungsten corrosion.

These Monopolar Microelectrodes of MicroProbes are also available in Platinum/Iridium, Elgiloy (an alloy similar to stainless steel), and Pure Iridium metal. As an alternative we provide them with a thin coat of Parylene-C insulation instead of the Polymide tubing. Each electrode is etched to a fine taper and tipped using a proprietary process to a specific impedance value. Four different tip profiles are available, see below.

The tip selection can provide subtle yet important changes to the performance of the electrode. It is recommended that first time users consider experimenting with different tip profiles to determine which works best for their recording or stimulation protocols.

For some applications concentric or bipolar electrodes (stereotrodes) are useful.

 

Monopolar Electrodes, Tungsten, Heat Treated Tapered Tip
(75 µm × 3")
With Polymide Tubing

Item

Length

Shaft Diameter

Tip Diameter

Impedance

Applications

Pkg of 10

WE3PT30.01H3

76 mm

0.126 mm

1-2 µm

0.01 MΩ

MultiUnit & ERP recording & Stim

WE3PT30.05H3

76 mm

0.126 mm

0.05 MΩ

WE3PT30.1H3

76 mm

0.126 mm

0.1 MΩ

WE3PT30.5H3

76 mm

0.126 mm

0.5 MΩ

Single & multiunit rec. & stim.

WE3PT31.0H3

76 mm

0.126 mm

1 µm

1.0 MΩ

WE3PT31.5H3

76 mm

0.126 mm

1.5 MΩ

WE3PT32.0H3

76 mm

0.126 mm

2.0 MΩ

WE3PT32.5H3

76 mm

0.126 mm

2.5 MΩ

Greater Selectivity - Small Cells

WE3PT33.0H3

76 mm

0.126 mm

3.0 MΩ

WE3PT35.0H3

76 mm

0.126 mm

5.0 MΩ

 

Monopolar Electrodes, Tungsten, Heat Treated Tapered Tip
(125 µm × 3")
With Polymide Tubing

Item

Length

Shaft Diameter

Tip Diameter

Impedance

Applications

Pkg of 10

WE3PT30.01H5

76 mm

0.216 mm

1-2 µm

0.01 MΩ

MultiUnit & ERP recording & Stim

WE3PT30.05H5

76 mm

0.216 mm

0.05 MΩ

WE3PT30.1H5

76 mm

0.216 mm

0.1 MΩ

WE3PT30.5H5

76 mm

0.216 mm

0.5 MΩ

Single & multiunit rec. & stim.

WE3PT31.0H5

76 mm

0.216 mm

1 µm

1.0 MΩ

WE3PT31.5H5

76 mm

0.216 mm

1.5 MΩ

WE3PT32.0H5

76 mm

0.216 mm

2.0 MΩ

WE3PT32.5H5

76 mm

0.216 mm

2.5 MΩ

Greater Selectivity - Small Cells

WE3PT33.0H5

76 mm

0.216 mm

3.0 MΩ

WE3PT35.0H5

76 mm

0.216 mm

5.0 MΩ

 

Monopolar Electrodes, Tungsten, Heat Treated Tapered Tip
(250 µm × 3")
With Polymide Tubing

Item

Length

Shaft Diameter

Tip Diameter

Impedance

Applications

Pkg of 10

WE3PT30.01A10

76 mm

0.356 mm

1-2 µm

0.01 MΩ

MultiUnit & ERP recording & Stim

WE3PT30.05A10

76 mm

0.356 mm

0.05 MΩ

WE3PT30.1A10

76 mm

0.356 mm

0.1 MΩ

WE3PT30.5A10

76 mm

0.356 mm

0.5 MΩ

Single & multiunit rec. & stim.

WE3PT31.0A10

76 mm

0.356 mm

1 µm

1.0 MΩ

WE3PT31.5A10

76 mm

0.356 mm

1.5 MΩ

WE3PT32.0A10

76 mm

0.356 mm

2.0 MΩ

WE3PT32.5A10

76 mm

0.356 mm

2.5 MΩ

Greater Selectivity - Small Cells

WE3PT33.0A10

76 mm

0.356 mm

3.0 MΩ

 

 

Monopolar Electrodes, Tungsten, Heat Treated Tapered Tip
(125 µm × 5")
With Polymide Tubing

Item

Length

Shaft Diameter

Tip Diameter

Impedance

Applications

Pkg of 10

WE5PT30.01H5

127 mm

0.216 mm

1-2 µm

0.01 MΩ

MultiUnit & ERP recording & Stim

WE5PT30.05H5

127 mm

0.216 mm

0.05 MΩ

WE5PT30.1H5

127 mm

0.216 mm

0.1 MΩ

WE5PT30.5H5

127 mm

0.216 mm

0.5 MΩ

Single & multiunit rec. & stim.

WE5PT31.0H5

127 mm

0.216 mm

1 µm

1.0 MΩ

WE5PT31.5H5

127 mm

0.216 mm

1.5 MΩ

WE5PT32.0H5

127 mm

0.216 mm

2.0 MΩ

WE5PT32.5H5

127 mm

0.216 mm

2.5 MΩ

Greater Selectivity - Small Cells

WE5PT33.0H5

127 mm

0.216 mm

3.0 MΩ

WE5PT35.0H5

127 mm

0.216 mm

5.0 MΩ

 

Monopolar Electrodes, Tungsten, Heat Treated Tapered Tip
(250 µm × 5")
With Polymide Tubing

Item

Length

Shaft Diameter

Tip Diameter

Impedance

Applications

Pkg of 10

WE5PT30.01A10

127 mm

0.356 mm

1-2 µm

0.01 MΩ

MultiUnit & ERP recording & Stim

WE5PT30.05A10

127 mm

0.356 mm

0.05 MΩ

WE5PT30.1A10

127 mm

0.356 mm

0.1 MΩ

WE5PT30.5A10

127 mm

0.356 mm

0.5 MΩ

Single & multiunit rec. & stim.

WE5PT31.0A10

127 mm

0.356 mm

1 µm

1.0 MΩ

WE5PT31.5A10

127 mm

0.356 mm

1.5 MΩ

WE5PT32.0A10

127 mm

0.356 mm

2.0 MΩ

WE5PT32.5A10

127 mm

0.356 mm

2.5 MΩ

Greater Selectivity - Small Cells

WE5PT33.0A10

127 mm

0.356 mm

3.0 MΩ

 

Common Tip Profiles:

Standard
A - STANDARD TIP PROFILE
The standard tip profile features a sharp yet robust point that offers versatile performance and an effective balance between penetration and durability.
Blunted
B - BLUNTED TIP PROFILE
The blunted electrodes are engineered to have a more rounded, bullet-shaped tip. For many applications the blunted tip can offer superior stimulation performance.
Tapered
H - HEAT TREATED TAPERED TIP PROFILE
The heat-treated electrodes are intended for those investigators who must penetrate their probes through tough membranes, such as the dura mater of larger mammals.
Extra Fine
F - EXTRA FINE TIP PROFILE
The extra-fine tip profile features a significantly sharper taper as well as a thinner insulation layer.

 

Also see:

Selecting the Optimum Electrode Configuration