ION-100/ION-100T |

|
|
Single
Channel Iontophoresis Generator
|
Dagan |
|
|
|
|
|
|
|
|
|
|
Features
|
|
|
+/-130
compliance voltage
External
Power Supply operates up to five units
ION-100T
is equipped with Timer functions Matching Pressure
Micro Injector PMI-100
|
Individual units can be "daisy chained"
together for multi-channel
setup
One
ION-100 can be used as a Sum channel Ideal for teaching labs
|
|
The
ION-100(T) uses an extremely accurate constant current
source operational amplifier with +130
compliance voltage. The current output range is
selectable between +/- 200nA and +/- 2000nA.
|
|
Specifications
|
|
|
The
front panel is arranged to facilitate easy operation.
The POSITIVE, NEGATIVE current controls and the eject
polarity controls operate as a team to determine both
the magnitude and the polarity of the passing and the
holding currents passed by the drug containing
electrode.
To eject a cationic drug (positively charged) it is
necessary to pass a positive current, to then prevent
diffusion of that same cationic drug a negative
"backing" or retaining current is required.
The converse is true for anionic drug, negative for
eject and positive for retain.
A "no" current flow situation can be
obtained ether by setting both POSITIVE & NEGATIVE
controls to 0nA on the dial or by placing the EJECT
POSITIVE/NEGATIVE toggle switch to OFF/EXT.
The EJECT/RETAIN switch provides a manual control over
the time period of drug injection. In the EJECT
position the preprogrammed EJECT current passes drug
through the micropipette barrel. The RETAIN position
supplies the preprogrammed RETAIN current to hold the
drug in the micropipette barrel.
If other than manual time control is desired, the
EJECT/RETAIN switch should be placed in the AUTO or
GATE position. In this position, the timing can be
controlled by ether the EJECT TIMER (ION-100T only) or
by the GATE input BNC on the back panel.
The GROUND push button switch shorts (grounds) out the
current generator and micropipette barrel.
External analog current programming is accomplished by
injecting +10 volt to -10 volt programming voltage
into the back panel EXT COMD BNC.
SUM Channel:
When
using 2 or more ION-100(T)'s together one can be
configured as a SUM channel. The SUM channel output
supplies a current equal in magnitude but opposite in
sign to the algebraic sum of the currents from the sum
outs of the other ION-100(T) in the SUM chain. To
configure several ION-100(T)'s together with one as a
SUM channel the SUM OUT of the first unit is plugged
into the SUM IN of the second unit and so on until the
last unit to be used as the SUM channel has the SUM
out of the previous unit is plugged into the EXT COMD
input of the SUM channel.
|
|
Current
Source Parameters
| Compliance
voltage |
260
V peak to peak |
| Maximum
current |
2000nA |
Maximum
electrode resistance |
|
|
|
| Output
Current |
200nA |
650
Meg Ohm |
| 2000nA |
65
Meg Ohm |
|
Current
Programming
| Front
panel |
Positive
and Negative 200nA/2000nA one-turn controls.
Scaled by Range switch |
| External |
200
nA/Volt, rear panel BNC. Maximum
input 10 volts (2000nA Command) |
| Meter |
Current
Monitor +/-1999 nA |
| Cabinet
Size |
2.7"
high, 7.5" wide, 9.7" deep |
| Power
Requirements |
115
or 230 VAC (selectable with internal switch),
50/60 Hz, 35 W |
|
|
PDF- File Iontophoresis
Systems